Previous product
Portrait

Smart ME 800

Multi-Energy floor standing tank. Designed for a range of applications and a multiple choice of energy sources.

  • TANK-IN-TANK TECHNOLOGY
  • The unique design of our Multi energy cylinder with it's large primary storage makes the Smart ME the perfect partner for solar, heat pumps, pellet burners, heat recovery systems, district heating applications and much more.
  • label_energy_EXT
  • label_energy_SOL
  • Tanks
  • Floor installation
# GTIN : 5400891001929
# P/N : 06625301
Label 2
  • Flexible design options for specifiers and installers.
  • Increased heating surface for rapid domestic hot water recovery.
  • Large primary volume allows for greater thermal storage.
  • Can be used as a low loss header for heating circuit.
  • Immersion heater in primary circuit (except Smart ME800).
  • 3kW or 6kW immersion heater options (except Smart ME800).
  • Stainless steel domestic hot water cylinder.
  • Carbon steel coil.
  • High quality insulation 50mm rigid polyurethane. (100mm Polyurethane insulation for models Smart ME600 and ME800).
  • Additional primary connections available for an underfloor heating circuit.
  • Anti-Legionella : Storage temperature > 60°C.
Schematic
  1. Primary hot water flow
  2. Primary return
  3. Coil flow
  4. Coil return
  5. Heating circuit flow
  6. Heating circuit return
  7. Drywell pocket for sensors
  8. Immersion heater connection (not available on SLME800)

Constructive characteristics

Smart ME 200 Smart ME 300 Smart ME 400 Smart ME 600 Smart ME 800
Capacity (total) L 203 303 395 606 800 L
Capacity (primary) L 95,7 165 219 365 517 L
Coil capacity L 8,3 12 12 16 20 L
Weight (empty) kg 68 99 120 180 220 kg
Max operating temperature °C 90 90 90 90 90 °C
Max operating pressure heating (primary) bar 3 4 4 4 4 bar
Max operating pressure (DHW) bar 8,6 8,6 8,6 8,6 8,6 bar
Max operating pressure (coil) bar 10 10 10 10 10 bar
Primary flow (EN 12897:2016) L/s 0,70 1,25 1,25 1,25 1,25 L/s
Primary heater pressure drop (EN12897:2016) mbar 41,6 51,2 53,5 55,6 58,5 mbar
Pressure drop coil mbar 460 533 533 186 216 mbar
Corresponding flow in coil L/h 3000 3000 3000 3000 3000 L/h
Connection - primary Ø" 1 F 1 F 1 F 1 F 1 F Ø"
Connection - DHW Ø" 3/4 M 3/4 M 3/4 M 3/4 M 1 ½ M Ø"
Connection - re-circulation / safety valve Ø" 3/4 M 3/4 M 3/4 M 3/4 M 1 ½ M Ø"
Connection - heating element Ø" 1 ½ F 1 ½ F 1 ½ F 1 ½ F - Ø"
Connection - coil Ø" 1 M 1 M 1 M 1 M 1 M Ø"
Heating surface coil 1,4 1,8 1,8 2,5 3

Heating characteristics

Smart ME 200 Smart ME 300 Smart ME 400 Smart ME 600 Smart ME 800
Reheat time (EN 12897:2016) min 10 10 10 10 10 min
Reheat performance (EN 12897:2016) kW 24,7 29,7 45,6 50,2 54 kW
Max absorbed heat (Heat source: coil) kW 16,3 19 25 29 35 kW
Max absorbed heat (Heat source: boiler) kW 31 32 43 48 73 kW

Domestic hot water performance

Smart ME 200 Smart ME 300 Smart ME 400 Smart ME 600 Smart ME 800
Peak flow at 40°C L/10’ 321 418 558 686 922 L/10’
Peak flow 1st hour at 40°C L/60’ 1063 1225 1633 1872 2666 L/60’
Continuous flow at 40°C L/h 890 967 1289 1423 2093 L/h
Peak flow at 45°C L/10’ 275 348 464 582 790 L/10’
Peak flow 1st hour at 45°C L/60’ 911 1003 1338 1559 2285 L/60’
Continuous flow at 45°C L/h 763 786 1048 1172 1794 L/h
Peak flow at 60°C L/10’ 161 206 274 358 504 L/10’
Peak flow 1st hour at 60°C L/60’ 536 590 786 935 1368 L/60’
Continuous flow at 60°C L/h 450 461 614 693 1037 L/h

Eco Design Fields

Smart ME 200 Smart ME 300 Smart ME 400 Smart ME 600 Smart ME 800
Standing loss (Energy label) W 57 77 87 120 134 W
Product Fiche

Technical brochure

Electrical connection heating elements 10800081 to 10800084 - Weerstand - Résistance - Immersion Heater

1.18MB – fr en nl it de es

Smart ME (SLME) - Installation, operations and maintenance instructions

2.69MB – en

Thermostat mounting kit

506.07kB

Ecodesign

Product Fiche

BIM Files

BIM Files

Find an installer

Get in touch with an installer for a free, no obligation estimate.

Call ACV

Need some answers? Talk to a specialist

Tel. +32 2 334 82 20